Display
zone
Operating mode or component
Specification
Evaluation
1
Glow plug system status
1111 1111
2
Glow period (in seconds)
xx,x s
---
3
Voltage supply from automatic glow peri-
od control unit
Approx. battery voltage
---
4
Coolant temperature
80.0...110.0°C
---
Evaluation: display group 12, display zone 1 - glow plug
system status
Note
Meaning of figures in 8-digit number block for status of glow
plug system:
Significance if display = 1
Dis-
play
show
s
Glow plug system status
0000
0000
Waiting for coolant temperature
0001
0000
Pre-heating
1011
0000
Post-heating
1111
0000
Intermediate heating
0011
0000
Standby-heating
1011
0001
Waiting for post-heating
1111
0001
Waiting for intermediate heating
0000
0001
Waiting for ECO start request (Economy)
0101
0000
No glow period
1000
0000
No heating for start-up
1111
1111
No heating
0111
0000
Heating for start-up
1101
0000
No post-heating
3