6.3.17 Display group 85
Display
zone
Operating mode or component
Value range
Evaluation
1
---
0...2550 m
---
2
---
0...255
---
3
---
0....255
---
4
Engine start counter
0 - ?
---
6.3.18 Display group 97
Display
zone
Operating mode or component
Value range
Evaluation
1
Diesel particulate filter, differential pres-
sure offset (only CPYA and CPYB)
-328 .. 325 mbar
---
2
Diesel particulate filter, old differential
pressure offset (only CPYA and CPYB)
-328 .. 325 mbar -
---
3
---
---
---
4
---
---
---
6.3.19 Display group 99 - exhaust gas tempera-
ture sender
Test prerequisites
● Engine running at idling speed.
● Engine warm, coolant temperature not below 80°C.
● Intake air temperature < 40°C.
Display
zone
Operating mode or component
Specification
Evaluation
1
Engine speed
880...1090 rpm
---
2
Exhaust gas temperature ahead of turbo-
charger
150...370 °C
3
---
---
---
4
Exhaust gas temperature ahead of diesel
particulate filter
130...310 °C
---
Evaluation: display group 99, display zone 2 - exhaust gas
temperature
Display shows
Possible cause of fault
Fault remedy
Deviation from
specification
◆
Exhaust temperature sender 1 -G235-
defective
– -G235- Check.
6.3.20 Display group 100 - diesel particulate filter,
exhaust gas temperature sender, pressure
differential sender
Test prerequisites
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
6 Measured value blocks, engine codes CPYA, CPYB, CPYC, CPYD, CPYE, CPYF, CPYG
121