Indicated on display
Possible cause of fault Possible effects
Fault remedy
Open circuit
◆
Open circuit or line
short-circuit
◆
-G28- defective
◆
-G31- defective
◆
Defective accelerator
position sender -G79-
◆
Defective exhaust
gas recirculation po-
tentiometer -G212-
◆
Defective exhaust
gas recirculation
valve -N18-
◆
Position sender for
charge pressure posi-
tioner -G581- defec-
tive
◆
Faults for sensors
connected to this
source are locked.
◆
Limp mode
– Check electrical con-
nection or sensor:
camshaft encoder; in-
take manifold flap; dif-
ferential pressure die-
sel particulate filter;
pedal encoder 1
– -G28- Check.
“Checking engine
speed sender -G28-”
on page 400
– -G31- Check.
“Checking charge
pressure sender
-G31-” on page 343
– -G79- Check.
“Checking accelerator
pedal position sender
-G79-, if fitted” on
page 316
“Checking exhaust
gas recirculation valve
-N18-” on page 437
check exhaust gas re-
circulation valve -N18-
– Check -N18-
trol diagnosis
“Checking position
sender for charge
pressure positioner
-G581-” on page 345
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
3 List of fault codes
57