Note
After eliminating faults the event memory must be read again as
follows and then cleared.
– Start engine and run at idling speed.
– Connect vehicle diagnostic tester, and select engine control
unit.
– Select diagnosis function “004-Read event memory”.
– Select diagnosis function “004.10-Clear event memory”.
Note
If the event memory will not erase there is a fault still in the sys-
tem and this must be rectified.
– Exit diagnosis function.
– Switch off ignition.
3
List of fault codes
Note
◆
The fault table is listed in ascending order according to the
5-digit V.A.G. fault code on the left.
◆
In addition, so-called P codes, e.g. P0118, are displayed as
well.
◆
For additional information on the fault types (e.g. “Open cir-
cuit/Short to Earth")”) refer to the
⇒
Operating manual for
vehicle diagnosis, testing and information system VAS 5051.
◆
If components are indicated as faulty: First check the wiring
and connectors to these components as well as the system
earth connections referring to current flow diagram. Only
when no fault can be located here should the component be
renewed. This is particularly relevant if faults are output as
“sporadic” (SP).
◆
The event memory must be cleared after rectifying existing
faults
Indicated on display:
00280/P0118 035
Coolant temperature sender -G62-
Signal too large
Sporadic fault
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
28
Repair Group 01 - Vehicle self-diagnosis