VD520 Series Inverter User Manual Function Parameter Table
- 57 -
reached
31: Accumulative power-on time
reached
32: Timing reached output
33: PLC circulation output
34: Frequency limit
35: Torque limit
36: Reverse running
37: AI1 input limit
38: AI1>AI2
39: Communication setting
40: Reserved
41: Timing braking (power on braking)
42: Inverter in running (jog no output)
F6-06
DO Output
Terminal
Effective State
Selection
Unit’s digit: HDO1
0: Positive logic
1: Anti-logic
Ten’s digit: RELAY1, same as above
Hundred’s digit: RELAY 2, same as
above
Thousand’s digit: DO1, same as
above
Ten thousand’s digit: reserved
0x00000
○
F6-07
HDO1 Closing
Delay
0.0s~3600.0s
0.0s
○
F6-08
T1 Closing
Delay
0.0s~3600.0s
0.0s
○
F6-09
T2 Closing
Delay
0.0s~3600.0s
0.0s
○
F6-10
DO1 Closing
Delay
0.0s~3600.0s
0.0s
○
F6-11
DO5 Closing
Delay
0.0s~3600.0s
0.0s
○
F6-12
HDO1 Output
Function
Selection
0: Running frequency
1: Set frequency
2: Output current (2 times of rated
motor current)
3: Output torque
4: Output power
5: Output voltage
6: PULSE input (100% corresponding
100.0kHz)
7: AI1
8: AI2
0
○
F6-13
AO1 Output
Function
Selection
0
○
F6-14
AO2 Output
Function
Selection
1
○