VD520 Series Inverter User Manual Parameter Description
- 183 -
b1-21
VDO Output Terminal
Effective State Selection
Unit’s digit: VDO1
0: Positive logic
1: Anti-logic
Ten’s digit: VDO2, same as above
Hundred’s digit: VDO3, same as
above
Thousand’s digit: VDO4, same as
above
Ten thousand’s digit: reserved
0x00000
○
b1-22
VDO1 Disconnection
Delay
0.0s~3600.0s
0.0s
○
b1-23
VDO2 Disconnection
Delay
0.0s~3600.0s
0.0s
○
b1-24
VDO3 Disconnection
Delay
0.0s~3600.0s
0.0s
○
b1-25
VDO4 Disconnection
Delay
0.0s~3600.0s
0.0s
○
b1-26
VDO5 Disconnection
Delay
0.0s~3600.0s
0.0s
○
Virtual digital output function, similar to the control panel DO output function, can be used to
cooperate with virtual digital quantity input VDIx, implement some simple logic control.
When virtual VDOx output function selection for 0, the output state of VDO1~VDO4 determined by
DI1~DI4 input status on the control panel, VDOx and Dix one to one corresponding at this point.
When virtual VDOx output function selection for not zero, the function setting and use methods of
VDOx is the same with the F6 group DO output related parameters, please refer to the related
parameters of the F6 group.
The same output valid state of the VDOx can selection positive logic or antilogic, setting through the
b1-10.
In VDIx application example, including the use of VDOx, please reference.