Function Parameter Table VD520 Series Inverter User Manual
- 52 -
F5 Input Terminal
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
F5-00
Terminal
Command Mode
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode 1
3: Three-line mode 2
4: Alternate control
5: Back and forth control
0
◎
F5-01
DI1 Input
Terminal
Function
Selection
0: No function
1: Forward running (FWD)
2: Reverse running (REV)
3: Three-line mode run control
4: Forward Jog (FJOG)
5: Reverse Jog (RJOG)
6: Coast to stop
7: Run pause
8: Fault reset (RESET)
9: External fault normally open input
10: External fault normally closed
input
11: Terminal UP
12: Terminal DOWN
13: UP/DOWN setting clear
14: Switching frequency source
15: Frequency source A switching
with preset frequency
16: Frequency source B switching
with preset frequency
17: MS reference terminal 1
18: MS reference terminal 2
19: MS reference terminal 3
20: MS reference terminal 4
21: Acceleration/deceleration time
selection terminal 1
22: Acceleration/deceleration time
selection terminal 2
23: PULSE frequency (Only effective
for HDI1)
24: Control command switch terminal
1
25: Control command switch terminal
2
26: Immediate DC braking
1
◎
F5-02
DI2 Input
Terminal
Function
Selection
2
◎
F5-03
DI3 Input
Terminal
Function
Selection
4
◎
F5-04
DI4 Input
Terminal
Function
Selection
6
◎
F5-05
DI5 Input
Terminal
Function
Selection
8
◎
F5-06
HdI1 Terminal
Function
Selection
0
◎
Содержание VD520 Series
Страница 2: ......