Parameter Description VD520 Series Inverter User Manual
- 164 -
FC Multi-reference and Simple PLC Parameters Group
FC-00
Multi-reference 0
-100.0%~100.0%
0.0%
○
FC-01
Multi-reference 1
-100.0%~100.0%
0.0%
○
FC-02
Multi-reference 2
-100.0%~100.0%
0.0%
○
FC-03
Multi-reference 3
-100.0%~100.0%
0.0%
○
FC-04
Multi-reference 4
-100.0%~100.0%
0.0%
○
FC-05
Multi-reference 5
-100.0%~100.0%
0.0%
○
FC-06
Multi-reference 6
-100.0%~100.0%
0.0%
○
FC-07
Multi-reference 7
-100.0%~100.0%
0.0%
○
FC-08
Multi-reference 8
-100.0%~100.0%
0.0%
○
FC-09
Multi-reference 9
-100.0%~100.0%
0.0%
○
FC-10
Multi-reference 10
-100.0%~100.0%
0.0%
○
FC-11
Multi-reference 11
-100.0%~100.0%
0.0%
○
FC-12
Multi-reference 12
-100.0%~100.0%
0.0%
○
FC-13
Multi-reference 13
-100.0%~100.0%
0.0%
○
FC-14
Multi-reference 14
-100.0%~100.0%
0.0%
○
FC-15
Multi-reference 15
-100.0%~100.0%
0.0%
○
Multi-reference can be used in three occasions: as the frequency source, the voltage source of V/F
separation and the set source of process PID.
Under three kinds of applications, the dimension of the multi reference is relative value, the range of
-100.0%~100.0%, when as the frequency source it is relative to the percentage of the maximum
frequency; when as the V/F separation voltage source, is relative to the percentage of the rated motor
voltage; and because PID is given as a relative value, the multi-reference as set source of PID don't
need a dimensional transformation.
Содержание VD520 Series
Страница 2: ......
Страница 9: ...VD520 Series Inverter User Manual Safety and Precautions 5 damage or performance reduce ...