Parameter Description VD520 Series Inverter User Manual
- 146 -
Ten thousand’s digit: communication
abnormal (18)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
F9-37
Fault Protection Action
Selection 2
Unit’s digit: reserved
Ten’s digit: parameter read-write
abnormal (21)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Hundred’s digit: running time reached
(27)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Thousand’s digit: reserved
Ten thousand’s digit: reserved
0x000
00
○
F9-38
Fault Protection Action
Selection 3
Unit’s digit: user-defined fault 1 (35)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
T
en’s digit: user-defined fault 1 (36)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Hundred’s digit: power on time reached
(28)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Thousand’s digit: offload (37)
0: Coast to stop
1: Stop according to stop mode
2: Decelerate to 7% of the rated motor
frequency continue running,
automatically restored to the set
frequency operation when no offload
Ten thousand’s digit: PID feedback lost
when running (18)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
0x000
00
○