VD520 Series Inverter User Manual Function Parameter Table
- 47 -
F1-24
Over-excitation
Effective Range
0: The whole is valid
1: Only overpressure stall enable
effectively
2: Only deceleration process
effectively
3: The whole is invalid
2
◎
F1-25
Over-excitation
Gain
0~200
100
○
F1-26
Over-excitation
Filter Coefficients
0~10
3
○
F1-27
Acceleration /
Deceleration Mode
0: Straight-line
acceleration/deceleration
1: S curve acceleration/deceleration A
2: S curve acceleration/deceleration B
0
◎
F1-28
Time Ratio of S
Curve Start
Segment
0.0%~(100.0%-F1-26)
30.0%
◎
F1-29
Time Ratio of S
Curve End
Segment
0.0%~(100.0%-F1-25)
30.0%
◎
F1-30
Zero Frequency
Voltage Output
Selection
0: Have voltage output
1: Non voltage output
0
○
F1-31
Jog Speed
Tracking Effective
Selection
0: Disabled
1: Enabled
1
○
F2 Motor 1 Parameter
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Propert
y
F2-00
Motor Type
Selection
0: Ordinary asynchronous motor
1: Frequency conversion
asynchronous motor
0
◎
F2-01
Rated Motor
Power
0.1kW~1000.0kW
Model
dependent
◎
F2-02
Rated Motor
Voltage
1V~2000V
Model
dependent
◎
F2-03
Rated Motor
Current
0.01A~655.35A (Inverter
power≤55kW)
0.1A~6553.5A (Inverter power>55kW)
Model
dependent
◎
F2-04
Rated Motor
Frequency
0.01Hz~max frequency
Model
dependent
◎