Function Parameter Table VD520 Series Inverter User Manual
- 80 -
A0 Motor 1 Torque Control .
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
A0-00
Speed/Torque
Control Mode
Selection
0: Speed control
1: Torque control
0
◎
A0-01
Torque Setting
Source
Selection under
the Torque
Control Mode
0: Digital setting (A0-02)
1: AI1
2: AI2
3: Reserved
4: PULSE
5: Communication setting
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
8: Keypad Potentiometer (the full
scale of option 1~7 corresponding
digital setting of A0-02)
0
◎
A0-02
Torque Digital
Setting under
the Torque
Control Mode
-200.0%~2000%
100.0%
○
A0-03
Max Frequency
Source
Selection under
the Torque
Control Forward
0: Digital setting (A0-04)
1: AI1
2: AI2
3: Reserved
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-04
Max Frequency
Digital Setting
under the
Torque Control
Forward
0.00Hz~max frequency
50.00Hz
○
A0-05
Max Frequency
Source
Selection under
the Torque
Control Reverse
0: Digital setting (A0-06)
1: AI1
2: AI2
3: Reserved
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎