- 42 -
Chapter 5 Function Parameter Table
The symbols in the function table are described as follows:
○
——It indicates that the parameter setup value can be modified when the inverter is in run state;
◎
——It indicates that the parameter setup value cannot be modified when the inverter is in the run
state;
●
——It indicates that the numerical value of the parameter is the actually measured value, which
cannot be modified;
☆
——It indicates this parameter is “Factory default parameter” and can be set only by the
manufacturer.
F0 Basic Parameter Group
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
F0-00
Motor Control
Mode
Led unit’s digit: motor 1
0: V/F control
1: SVC
Led ten’s digit: motor 2
0: V/F control
1: SVC
0x00
◎
F0-01
Running
Command Source
0: Control panel command source
(L/R OFF)
1: Terminal command source (L/R
ON)
2: communication command source
(L/R flashes)
0
○
F0-02
Main Frequency
Source A
Selection
0: Digital setting(F0-09, UP/DOWN
can be modified, no memory when
power failure)
1: Digital setting(F0-09, UP/DOWN
can be modified, memory when power
failure)
2: AI1
3: AI2
4: Reserved
5: PULSE setting
6: MS reference
7: Simple PLC
8: PID
9: Communication setting
10: Keypad potentiometer
10
◎
F0-03
Main Frequency
A Gain
0.000~10.000
1.000
○