VD520 Series Inverter User Manual Function Parameter Table
- 73 -
Fb-42
Wakeup
Frequency
Dormancy frequency (Fb-44)~max
frequency (F0-10)
0.00Hz
○
Fb-43
Wakeup Delay
Time
0.0s~6500.0s
0.0s
○
Fb-44
Dormancy
Frequency
0.00Hz~wakeup frequency (Fb-42)
0.00Hz
○
Fb-45
Dormancy
Delay Time
0.0s~6500.0s
0.0s
○
Fb-48
Timing Braking
Frequency
0.00Hz~50.00Hz
1.50Hz
○
Fb-49
Timing Braking
Time
0.0s~60.0s
2.0s
○
Fb-50
Terminal Jog
Priority
0: Disabled
1: Enabled
1
○
Fb-51
Swing
Frequency
Setting Method
0: Relative to center frequency
1: Relative to max frequency
0
○
Fb-52
Swing
Frequency
Amplitude
0.0%~100.0%
0.0%
○
Fb-53
Jumping
Frequency
Amplitude
0.0%~50.0%
0.0%
○
Fb-54
Swing
Frequency
Cycle
0.1s~3000.0s
10.0s
○
Fb-55
Triangular Wave
of Swing
Frequency Rise
Time
0.1%~100.0%
50.0%
○
Fb-56
Set Length
0m~65535m
1000m
○
Fb-57
Actual Length
0m~65535m
0m
○
Fb-58
Number of
Pulse per Meter
0.1~6553.5
100.0
○
Fb-59
Set Count Value
1~65535
1000
○
Fb-60
Designated
Count Value
1~65535
1000
○
FC Multi-reference and Simple PLC
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
FC-00
Multi-reference
0
-100.0%~100.0%
0.0%
○