Troubleshooting
147
Spreading
tracks visible
among the
crops
Average quality fertiliser. 80% of the
granules with a diameter between 2.0 -
4.75 mm
Determine the distribution and spread
with small working widths if possible
54
Blend of fertiliser types used. A blend can
become unmixed again or types of
fertiliser could contain varying spreading
qualities.
Check the type, pattern and distribution.
Spread with smaller working widths as far
as possible
52,
54
New type of fertiliser spread with the
same settings as the previous type.
Quality varies greatly between types.
Determine the characteristics of the
fertiliser, look for the relevant spreading
chart and set the spreader again
52
57
Use of wrong spreading chart
Determine the characteristics of the
fertiliser and select the correct spreading
chart
52,
55
Working with unfavourable weather
conditions: high levels of humidity, rain,
heat or high wind speeds (> 5 m/sec)
Only work under good weather conditions
Incorrect overlapping of the spreading
pattern
Always set the driving tracks before
spreading
101
Horizontal/vertical settings of the machine
not correct
Check if the machine is standing level
horizontally and vertically, unless the
spreading chart indicates otherwise
47,
71,
97
Spreader not set to the correct height
Check and set to the correct working
height (75 cm above the crops or soil) and
inclination
97,
71
Working width incorrect
Check the discharge points (left and right)
and the PTO shaft rpm
62,
71
Worn or missing vanes
Check the vanes
60
Tyre pressure on the left and right not the
same
Check the tyre pressure
Reduce the spreading disc rpm with the
loss at the safety clutch
Check if the spreading discs are turning
smoothly. Check the safety clutch
132,
44
The setting mechanism of the discharge
point is not set well
Perform the »Check the setting
mechanism of the discharge point«
137
The dosing mechanism is not set well
Perform the »Check the settings of the
dosing mechanism«
132
Machine
makes a noise
while running
Discharge bushing makes contact with
the spreading disc
Adjust the discharge bushing
132
Spreader put down with filled hopper
Repair the machine. Set the dosing
mechanism and discharge point again
132,
137
Spreading disc hidden/ out of balance
Check the spreading discs for damage
and for the presence of all the vanes
60
Build-up of fertiliser at the agitator and/or
spreading discs
Remove the fertiliser. Clean the machine
well after each use.
119
Problem
Possible cause
Solution
Pag
e
Содержание RO-C 1400