Maintenance
141
Put hand through a dosing opening and support the fertiliser
bearing ring so that it will not drop.
Remove the 3 fastening bolts from the seal rings.
Remove the metal seal rings.
Replace the fertiliser seal.
Put the metal seal rings back in position.
Put the 3 fastening bolts back in place.
T
IP
You can let go of the bearing ring after the first fastening bolt has been
put back in place.
Put the agitator back into the agitator axle.
Check the connections as described in
→
paragraph »Check the settings of the dosing mechanism« on page
132.