Before first use
39
Calibration container
The calibration container is used to control the dosing setting of the
machine.
The calibration container must be mounted on the left spreading disc
for the calibration test.
Remove the vanes.
Turn the nuts on the bolts on which the gearbox is mounted to the
turning rod back 5 mm.
Push the bolts back as far as possible.
Hook the support behind the heads of the bolts.
Adjust the height of the support. The top end of the support must
be on the same height as the top end of the turning rod.
Fasten the nuts on the bolts again.
Note
Mount the support carefully so that the position of the gearbox would
not be changed!
Place the calibration container.
Fix the locks between the two halves.
Turn the other spreading disc by hand and listen if the spreading
disc in the calibration container is making contact with the
container.
Turn the lock nut upwards.
Turn the settings knob upwards or downwards until you can hear
that the spreading disc is no longer touching the calibration
container.
Turn the lock nut again.
Calibration container
S
Closing
support for the calibration container
driving rod
Lock nut
S
Settings knob