4
vacon • 28
Technical data
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
4.2.2
Inverter units
4.2.2.1
VACON
®
NX Liquid-Cooled Inverter Unit – Mains voltage 465—800 VDC
I
th
= Thermal maximum continuous RMS current. Dimensioning can be done according to this current if the
process does not require any overloadability or the process does not include any load variation.
Table 11. Power ratings of VACON
®
NX Liquid-Cooled inverter unit, supply voltage 540—675 VDC
Mains voltage 465-800 VDC
AC drive type
Drive output
Power loss
c/a/T
*)
[kW]
Chassis
Current
Motor output power
Thermal
I
th
[A]
Rated cont. I
L
[A]
Rated cont. I
H
[A]
Optimum
motor at I
th
(540 VDC) [kW]
Optimum
motor at I
th
(675 VDC) [kW]
0016_5
16
15
11
7.5
11
0.4/0.2/0.6
CH3
0022_5
22
20
15
11
15
0.5/0.2/0.7
CH3
0031_5
31
28
21
15
18.5
0.7/0.2/0.9
CH3
0038_5
38
35
25
18.5
22
0.8/0.2/1.0
CH3
0045_5
45
41
30
22
30
1.0/0.3/1.3
CH3
0061_5
61
55
41
30
37
1.3/0.3/1.5
CH3
0072_5
72
65
48
37
45
1.2/0.3/1.5
CH4
0087_5
87
79
58
45
55
1.5/0.3/1.8
CH4
0105_5
105
95
70
55
75
1.8/0.3/2.1
CH4
0140_5
140
127
93
75
90
2.3/0.3/2.6
CH4
0168_5
168
153
112
90
110
2.5/0.3/2.8
CH5
0205_5
205
186
137
110
132
3.0/0.4/3.4
CH5
0261_5
261
237
174
132
160
4.0/0.4/4.4
CH5
0300_5
300
273
200
160
200
4.5/0.4/4.9
CH61
0385_5
385
350
257
200
250
5.5/0.5/6.0
CH61
0460_5
460
418
307
250
315
5.5/0.5/6.0
CH62
0520_5
520
473
347
250
355
6.5/0.5/7.0
CH62
0590_5
590
536
393
315
400
7.5/0.6/8.1
CH62
0650_5
650
591
433
355
450
8.5/0.6/9.1
CH62
0730_5
730
664
487
400
500
10.0/0.7/10.7
CH62
0820_5
820
745
547
450
560
12.5/0.8/13.3
CH63
0920_5
920
836
613
500
600
14.4/0.9/15.3
CH63
1030_5
1030
936
687
560
700
16.5/1.0/17.5
CH63
1150_5
1150
1045
766
600
750
18.4/1.1/19.5
CH63
1370_5
1370
1245
913
700
900
15.5/1.0/16.5
CH64
1640_5
1640
1491
1093
900
1100
19.5/1.2/20.7
CH64
2060_5
2060
1873
1373
1100
1400
26.5/1.5/28.0
CH64
2300_5
2300
2091
1533
1250
1500
29.6/1.7/31.3
CH64
2470_5
2470
2245
1647
1300
1600
36.0/2.0/38.0
2*CH64
2950_5
2950
2681
1967
1550
1950
39.0/2.4/41.4
2*CH64
3710_5
3710
3372
2473
1950
2450
48.0/2.7/50.7
2*CH64
4140_5
4140
3763
2760
2150
2700
53.0/3.0/56.0
2*CH64