Installation
vacon • 63
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
5
5.2.2.1
Pressure losses
Figure 29. Pressure loss, CH6x
Table 22. Pressure losses; CH6x
CH6x with standard 1.5m hoses and optional fast connectors TEMA
Volume
flow rate
(l/min)
Pressure
loss;
Tema,
inflow
(bar)
Pressure
loss; inflow
hose (bar)
Pressure
loss;
element
(bar)
Pressure
loss;
outflow
hose: (bar)
Pressure
loss; Tema,
outflow
(bar)
Pressure
loss total
(inflow
hose,
element
and
outflow
hose) (bar)
Pressure
loss total
(Tema,
inflow and
outflow
hoses and
element)
(bar)
40.0 0.59
0.30
0.28
0.29
0.51
0.87
1.96
30.0 0.30
0.17
0.16
0.16
0.25
0.49
1.04
20.0 0.10
0.09
0.08
0.07
0.09
0.24
0.43
17.0 0.06
0.07
0.06
0.03
0.07
0.16
0.29
CH6; Pressure loss
10,0
15,0
20,0
25,0
30,0
35,0
40,0
45,0
0,00
0,50
1,00
1,50
2,00
2,50
Pressure loss, bar
Vo
lu
me
f
lo
w
r
a
te
, l/m
in
Pressure loss; Tema, inflow
(SET-SEL) (bar)
Pressure loss; inflow hose (SEL-
SEE) (bar)
Pressure loss; element (SEE-
PEJ)
Pressure loss; outflow hose:
(PEJ-PLJ) (bar)
Pressure loss; Tema, outflow
(PLJ-PTJ)(bar)
Pressure loss total (inflow hose,
ele-ment and outflow hose)
Pressure loss total (Tema, inflow
and outflow hoses and element)
11337_uk
Содержание NX
Страница 1: ...vacon nx ac drives liquid cooled drives user manual ...
Страница 2: ......