6.4 Quick Start
The following procedure is for operators using simple applications, who would like to get started quickly.
Be sure to read and understand all the sections in this chapter before proceeding with these instructions.
If you are using remote operators, substitute the speed potentiometer for the INC and DEC keys (up and
down arrows), and the remote Run/Stop switch for the FWD key in the following instructions.
1.
Follow all precautions and procedures in “Receiving and Installation” on page 19.
2.
Find the motor nameplate, and using parameters 509 (Rated Mtr Volt), 510 (Rated
Mtr FLA), 511 (Rated Mtr RPM), and 515 (Power Factor), set up the motor parame-
ters appropriately. Parameter 514 (Motor RS) should also be set up accurately so
the drive can run its routine to measure motor stator resistance. (See “Measuring
Stator Resistance (RS Measurement)” on page 46.
3.
Apply AC power to the input terminals. For about 2 seconds the display will show all
segments active. The display then changes to zeros.
4.
The factory settings are for keypad-only operation in the forward direction – that is,
the REV key is disabled. Press the FWD key, which causes the FWD indicator to il-
luminate.
5.
Press the INC key to increase the desired running frequency. When the display gets
to 0.1 Hz, the drive starts to produce an output.
6.
When the motor starts to turn, check the rotation. If the motor is turning in the
wrong direction, press STOP, remove AC power, and wait for all indicators to go out.
After the STATUS indicator has gone out, reverse any two of the motor leads at T1/
U, T2/V, or T3/W.
7.
The Vacon 50X drive is preset to run a typical NEMA B 4-pole induction motor to a
maximum speed of 60.0 Hz with both acceleration and deceleration times set to 5.0
seconds.
8.
Use the INC and DEC keys to set the proper running speed of the motor and the FWD
and STOP keys to control its operation.
CAUTION
IMPROPER EQUIPMENT COORDINATION
Verify that proper voltage is connected to the drive before
applying power.
Failure to observe this instruction can result in injury or
equipment damage.
Содержание 50X
Страница 1: ......
Страница 5: ...introduction vacon 4 24 hour support 358 0 40 837 1150 Email vacon vacon com 1 ...
Страница 23: ...receiving and installation vacon 22 24 hour support 358 0 40 837 1150 Email vacon vacon com 3 ...
Страница 30: ...29 vacon connections Tel 358 0 201 2121 Fax 358 0 201 212205 4 Figure 11 Power Terminals Size 4 and 5 ...
Страница 39: ...connections vacon 38 24 hour support 358 0 40 837 1150 Email vacon vacon com 4 ...
Страница 49: ...keypad operation and programming vacon 48 24 hour support 358 0 40 837 1150 Email vacon vacon com 5 ...
Страница 59: ...using macro mode and getting a quick start vacon 58 24 hour support 358 0 40 837 1150 Email vacon vacon com 6 ...
Страница 101: ...vacon 50x parameters vacon 100 24 hour support 358 0 40 837 1150 Email vacon vacon com 7 ...
Страница 107: ...hexadecimal to binary conversion vacon 106 24 hour support 358 0 40 837 1150 Email vacon vacon com 9 ...
Страница 113: ...eu declaration of conformity vacon 112 24 hour support 358 0 40 837 1150 Email vacon vacon com 11 ...
Страница 131: ...summary of vacon 50x parameters vacon 130 24 hour support 358 0 40 837 1150 Email vacon vacon com 12 ...
Страница 132: ......