5.5 Programming
5.5.1 Accessing Parameters
When PROG (or SHIFT+PROG) is pressed after application of power or a fault reset, parameter 201, Input
Mode, is always the first parameter displayed. Figure 21 shows a typical programming display.
Figure 21: Typical Programming Display
If a different parameter is accessed and Program mode is exited, that parameter is the first one displayed
the next time Program mode is entered. The drive remembers a different “last parameter accessed” for
Levels 1 and 2.
5.5.2 Changing the Display Scroll Rate
Pressing the INC or DEC keys (up or down arrows) arrows causes the display to scroll at a slow rate. To
increase the scroll rate, hold the SHIFT key at the same time that you press the INC key. Release the
SHIFT key to return to the slow scroll rate. This procedure works in all programming and operation
modes.
5.5.3 Programming Procedure
To program the value of a parameter, follow these steps:
1.
Press the Program (PROG) key to enter Level 1 Program mode. To enter Level 2,
press SHIFT+PROG. The P indicator will appear on the display. You must enter one
level of programming or the other; you cannot switch between levels without exiting
Program mode.
Note that some parameters cannot be changed in Run mode. For example, if you
wish to program parameter 201, Input Mode, you must stop the drive before
beginning programming. Refer to the Parameter Summary Table at the front of
this manual to see which parameters cannot be changed in Run mode (they
appear as shaded entries in the table).
2.
Press the INC/DEC keys to access the desired parameter.
3.
Press the SHIFT key to allow the value to be changed. The P indicator starts to blink.
4.
Press the INC/DEC keys to select the new value.
5.
Press the ENTER key to store the new value. The display shows “Stored” for one
second.
6.
Press the PROG key to exit the Program mode, or the INC/DEC keys to select a new
parameter.
To program a text parameter, follow these steps:
1.
Like other parameters, text parameters use the INC/DEC (up/down arrow) and
SHIFT keys for editing. A line appears under the character that you are changing.
2.
Press SHIFT to advance to the next character that you want to change.
3.
Use the INC or DEC keys to change the character value.
4.
Press ENTER to store the edited text.
Содержание 50X
Страница 1: ......
Страница 5: ...introduction vacon 4 24 hour support 358 0 40 837 1150 Email vacon vacon com 1 ...
Страница 23: ...receiving and installation vacon 22 24 hour support 358 0 40 837 1150 Email vacon vacon com 3 ...
Страница 30: ...29 vacon connections Tel 358 0 201 2121 Fax 358 0 201 212205 4 Figure 11 Power Terminals Size 4 and 5 ...
Страница 39: ...connections vacon 38 24 hour support 358 0 40 837 1150 Email vacon vacon com 4 ...
Страница 49: ...keypad operation and programming vacon 48 24 hour support 358 0 40 837 1150 Email vacon vacon com 5 ...
Страница 59: ...using macro mode and getting a quick start vacon 58 24 hour support 358 0 40 837 1150 Email vacon vacon com 6 ...
Страница 101: ...vacon 50x parameters vacon 100 24 hour support 358 0 40 837 1150 Email vacon vacon com 7 ...
Страница 107: ...hexadecimal to binary conversion vacon 106 24 hour support 358 0 40 837 1150 Email vacon vacon com 9 ...
Страница 113: ...eu declaration of conformity vacon 112 24 hour support 358 0 40 837 1150 Email vacon vacon com 11 ...
Страница 131: ...summary of vacon 50x parameters vacon 130 24 hour support 358 0 40 837 1150 Email vacon vacon com 12 ...
Страница 132: ......