Configure Stratagy
System Parameters
4-28
Stratagy I&M 06/02
user_log
Whether the system makes an entry in the specified log file whenever a User ID is
accessed via DTMF. The log entry consists of the date, time and User ID. This is
useful for creating a data file that can later be analyzed for call distributions and
dates, days, and times mailboxes are accessed.
Note When active, grows quickly. Archive or delete frequently.
Possible values: valid DOS file name. The single quotes are required.
Default: ‘USERID.LOG’(To enable, remove the starting # and set the value.)
Serial Port Definition
baud1
Baud rate for logical serial port 1. This operates on the physical COM port as
defined by serial_port1.
Possible values: 300, 1200, 2400, 9600, 19200.
Default: 2400
baud2
Baud rate for logical serial port 2. This operates on the physical COM port as
defined by serial_port2.
Possible values: 300, 1200, 2400, 9600, 19200.
Default: 2400
databits1
Number of data bits for logical serial port 1.
Possible values: 7, 8
Default: 8
databits2
Number of data bits for logical serial port 2.
Possible values: 7, 8
Default: 8
parity1
Parity to use for logical serial port 1.
Possible values: none, even, odd, mark, space
Default: none
parity2
Parity to use for logical serial port 2.
Possible values: none, even, odd, mark, space
Default: none
serial_port1
In order for Stratagy to communicate with peripheral devices connected to COM/
RS232 ports, it needs to know which ports are connected. There is a mapping from
the port that Stratagy knows to the physical port on the computer. This mapping is
defined by this parameter. To define serial port 1 as active, simply define the COM
port where it should be mapped.
Examples: Set this parameter to 1 to connect serial port 1 (Stratagy) to COM1.
Possible values: 0 (not connected), 1 (COM1), 2 (COM2), 3 (COM3), 4 (COM4)
Default: 0
serial_port2
In order for Stratagy to communicate with peripheral devices connected to COM/
RS232 ports, it needs to know which ports are connected. There is a mapping from
the port that Stratagy knows to the physical port on the computer. This mapping is
defined by this parameter. To define serial port 2 as active, simply define the COM
port where it should be mapped.
Examples: Set this parameter to 2 to connect serial port 2 (Stratagy) to COM2.
Possible values: 0 (not connected), 1 (COM1), 2 (COM2), 3 (COM3), 4 (COM4)
Default: 0
Parameter
Description
Содержание Stratagy Flash
Страница 20: ...Contents Index viii Stratagy I M 06 02 ...
Страница 24: ...Introduction Related Documents Media xii Stratagy I M 06 02 ...
Страница 52: ...Installation Step 16 Optional Back up Database Mailbox Names and Greetings 2 18 Stratagy I M 06 02 ...
Страница 102: ...Configure Stratagy SMDI Serial Integration 4 38 Stratagy I M 06 02 ...
Страница 204: ...Customization Examples Auto Menu Examples 8 28 Stratagy I M 06 02 ...
Страница 214: ...AMIS Networking AmisNodeList 9 10 Stratagy I M 06 02 ...
Страница 222: ...System Reports Report Menu Field Descriptions 10 8 Stratagy I M 06 02 ...
Страница 250: ...Special Greeting User ID Mailboxes Operator Mailbox Greeting B 6 Stratagy I M 06 02 ...