3.Printer-specific Adjustments
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
© 2018 TOSHIBA TEC CORPORATION All rights reserved
3-42
(j) Place the printed chart face down on the original glass aligning it with its left rear corner, so that
two black rectangular marks are on the left side.
(k) Press the [START] button on the control panel.
• The calibration begins. Do not operate the equipment until the message “Scanning and
calibrating” disappears.
• If the chart is not properly placed, the message “Set chart correctly” is displayed on the
control panel. In this case, return to step (j) and realign the chart.
Caution after the adjustment
Nothing in particular