EXTERNAL MIXER/PEAKING. In active mode, bias for
external waveguide mixers is provided at the EXT MIXER
connection. Activate the External Mixer mode by changing
the FREQUENCY RANGE to 18—26 GHz and then mea
sure the bias with a VOM between the center conductor and
ground of the EXT MIXER port. Bias should range from
about -2 .0 to +1.0 V as the PEAKING control is varied. If
your mixer requires positive-going bias, the 492 bias polarity
can be reversed. Contact your local Tektronix Field
Representative.
NOTE
Due to residual magnetism buildup in the 1st (YIG)
oscillator tuning coils, accuracy o f the frequency
readout should be checked after the tuning coil has
been degaussed by pressing the DEGAUSS button.
Degauss when the FREQ SPAN/DIV is either 2 MHz
or 1 MHz before reducing the FREQ SPAN/DIV to
500 kHz.
Calibration—492/492P Service Vol. 1 (SN B030000 & up)
Performance Check
If the instrument has a preselector (Option 01), the con
trol also varies the preselector tuning to augment tracking
for the coaxial bands (0—21 GHz).
This completes the functional check of the front-panel
controls and push buttons.
2. Check Frequency Readout Accuracy for
492/492P and Tune Accuracy of 492P Only
Readout accuracy +(5 MHz 20% Span/Div) χ n or
±(
0
.
2
% of center frequency +
2 0
% of the span/division)
whichever is greater. Tune accuracy (492P only) is ± (7% of
tune amount)n or ±(150 kHz)n whichever is greater, “n” is
the harmonic number of the 1 st LO that is used in the first
conversion. Table 3-2 lists “n" and bands.
Table 3-2
HARMONIC NUMBER (n) vs FREQUENCY RANGE
a.
Test equipment setup is shown in Fig. 3-1. Set the
front-panel controls as follows, then apply the comb gener
ator output to the RF INPUT.
Band
Frequency Range
n
1
0.0—4.2 GHz (0.0— 1.8 GHz, Option 01)
1
2
1.7—5.5 GHz
1
3
3.0—7.1 GHz
1
4
5.4—18 GHz
3
5
15—21 GHz
3
6
a
18.0—26.5 GHz
6
7a 26—40 GHz
1 0
8
“
40—60 GHz
1 0
9a
60—90 GHz
15
1 0
"
90—140 GHz
23
1 1
a
140—220 GHz
37
FREQUENCY RANGE
FREQUENCY
FREQ SPAN/DIV
AUTO RESOLUTION
MIN RF ATTEN
Vertical Display
Video Filter
TIME/DIV
Digital Storage (Option 02)
0—4.2 GHz
(0— 1.8 GHz
Option 01)
1.0 GHz
200 MHz
On
20 dB
10 dB/DIV
WIDE
AUTO
VIEW A/VIEW B
‘ External Mixer required.
b.
Tune the 1.0 GHz comb line to center screen. De
crease the FREQ SPAN/DIV to 2 MHz or 1 MHz, keeping
the 1.0 GHz signal centered. Press the DEGAUSS button,
decrease the FREQ SPAN/DIV to 500 kHz, and center the
signal under the frequency dot.
c.
Press the IDENTIFY 500 kHz/ONLY button to verify
that the signal is a true response. Deactivate the identify
feature. If the signal is true, activate the frequency CAL
push button.
d.
Calibrate the frequency readout by adjusting the fre
quency control for a readout of 1.000 GHz. Deactivate the
CAL pushbutton.
e.
Return tne FP.EQ SPAN/DIV control to 200 MHz and
tune the FREQUENCY to the next comb line (1.5 GHz). De
crease the FREQ SPAN/DIV to 2 MHz, degauss the tuning
coils, then decrease the span to 500 kHz/div and center the
comb line under the frequency dot. Then press the IDENTI
FY 500 kHz/ONLY push button to verify that the signal is a
true response. If true, check the frequency readout accura
cy. If a spurious response, tune to the next marker and
check. Readout must equal 1.500 GHz ± (5 MHz + 20%
Span/Div) x n or; ±(0.2% of Center frequency + 20%
Span/Div) whichever is greater.
REV JUN 1982
3-7
Содержание 492, 492P
Страница 12: ...492 492P Service Vol I SN B030000 up The 492 492P Spectrum Analyzer xii REV AUG 1981 ...
Страница 244: ...Theory of Operation 492 492P Service Vol 1 SN B030000 up REV AUG 1981 5 81 ...
Страница 256: ...Theory of Operation 492 492P Service Vol 1 SN B030000 up Fig 5 40 Frequency control encoder timing ...
Страница 263: ...Theory of Operation 492 492P Service Vol 1 SN B030000 up Fig 5 43 9914 GPIA block diagram 5 100 REV AUG 1981 ...
Страница 299: ...Product 492 Ser 1 Date 2 12 85 Change Ref M55287 Fig 5 28 Basic tune voltage converter Page 2 of 6 ...