Fig. 4-12. LO section of 629 MHz converter showing test points and connectors.
tween desired and actual, divided by 2 MHz, equals the
number of minor divisions from the line end for the new cut.
Make a cut across the line and check that the new frequen
cy is between 723.100 and 723.900 MHz. Repeat as
necessary.
g.
Cover the 719 MHz oscillator cavity with the 829 MHz
Converter cover, press down to ensure good shielding, and
note the frequency readout of the counter. Frequency
should fall within 723.600 and 724.400 MHz.
h.
Reconnect P234 (100 MHz) and P237 (2182 MHz)
and confirm that phaselock is operating by noting that the
voltage on TP1011 is between 6.75 and 7.5 V. This com
pletes the adjustment of the 719 MHz LO. Replace the cov
er and reinstall the 829 MHz converter assembly.
4. 829 MHz Coaxial Bandpass Filter Adjustment
NOTE
This procedure is necessary if the position of one of
the variable capacitor loops (tabs) has been altered,
changing the bandpass characteristics of the filter.
4-22
REV JUN 1983
Содержание 492, 492P
Страница 12: ...492 492P Service Vol I SN B030000 up The 492 492P Spectrum Analyzer xii REV AUG 1981 ...
Страница 244: ...Theory of Operation 492 492P Service Vol 1 SN B030000 up REV AUG 1981 5 81 ...
Страница 256: ...Theory of Operation 492 492P Service Vol 1 SN B030000 up Fig 5 40 Frequency control encoder timing ...
Страница 263: ...Theory of Operation 492 492P Service Vol 1 SN B030000 up Fig 5 43 9914 GPIA block diagram 5 100 REV AUG 1981 ...
Страница 299: ...Product 492 Ser 1 Date 2 12 85 Change Ref M55287 Fig 5 28 Basic tune voltage converter Page 2 of 6 ...