TP16-256
- Installer Manual
Control by Keypoint
7-11
7.4.2 DISARMING
7.4.2.1 DISARMING WITH CODE
Enter a valid code (master or standard user code enabled for the programs armed),
e.g. master code (default code 12345):
+
12345
The green LED 5 is lit.
For the 8 seconds to come it is possible to select the programs to be armed/disarmed
(pressing the program number the first time the program is selected, pressing it the
second time it is deselected). On every keystroke the counter is reset.
Select the programs to be disarmed, e.g.:
+
1 3
After 8 seconds the red LED corresponding to the programs disarmed are switched off
and the programs return to stand-by.
+
#
to confirm the selection and stop the counter without waiting for 8 seconds
7.4.2.2 DISARMING UNDER DURESS (IF ENABLED)
In case of robbery, it is possible to simulate disarming of the system and release
simultaneously a hold-up alarm.
For this enter the master code or a standard user code (enabled for the programs
armed) reducing the last digit by one unit, e.g. master code (default code 12345):
+
12344
The control panel is apparently disarmed, i.e. all the program LED are switched off,
and if programmed appropriately by the installer, the logic outputs OUT1 or OUT2 of
the CPU board and all the modules connected and a telephone call for hold-up alarm
are activated.
7.4.3 BY-PASS
When the control panel is armed, it is possible to deactivate temporaneously part of
the system. Upon activation of the by-pass, the zones enabled for by-pass and
included in the program/s armed and partset are deactivated. The other zones are not
affected.
The exclusion of zones persists until deactivation of the by-pass or disarming of the
programs they are included in.
7.4.3.1 ACTIVATION OF BY-PASS WITH CODE
Enter a code enabled for by-pass (master or standard user code enabled for the
programs armed) followed by the number of the program to be partset, e.g.:
+
66778
+
1
For the time the by-pass is active the corresponding program LED is blinking.
7.4.3.2 ACTIVATION OF BY-PASS DURING THE ACCESS PERIODS
It is possible to define up to 8 access periods of the codes. As a consequence, the
codes are enabled for by-pass during the access periods associated by the installer or
holder of the master code only.
WARNING
Outside the access periods associated the codes are not accepted by control panel and any attempt
at acceding to the system will have no effect.
When trying to do so, the system ignores the command.
The green LED 5 remains lit and the red program LED remain off.
After 5 seconds, the electronic keypad returns to stand-by.
WARNING
Whereas the master code is always enabled for all the programs, the standard user codes control
merely those programs they have been enabled for by the installer or the holder of the master code.
WARNING
The zones excluded are those associated to the by-pass function and included in the program/s
selected.
Содержание TP16-256
Страница 4: ...IV Installer Manual TP16 256...
Страница 12: ...Index Installer Manual TP16 256 8...
Страница 16: ...General Features Installer Manual TP16 256 1 4...
Страница 18: ...Hardware Installer Manual TP16 256 2 2...
Страница 30: ...Hardware Installer Manual TP16 256 2 14...
Страница 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Страница 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Страница 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Страница 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Страница 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Страница 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Страница 86: ...Set up Installer Manual TP16 256 3 6...
Страница 91: ...TP16 256 Installer Manual Set up 3 11...
Страница 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Страница 196: ...Control by Console Installer Manual TP16 256 6 16...
Страница 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Страница 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Страница 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Страница 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Страница 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Страница 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...