![Tecnoalarm TP16-256 Скачать руководство пользователя страница 188](http://html1.mh-extra.com/html/tecnoalarm/tp16-256/tp16-256_installer-manual_1071788188.webp)
Control by Console
Installer Manual -
TP16-256
6-8
6.1.3 QUICK ARMING (IF ENABLED)
It is possible to speed up the arming process by pressing the key * (star) followed by
the program number, e.g.:
+
*1
+
*2
Repeat the command for all the programs to be armed.
6.1.4 ARMING THROUGH KEY ZONE
The control panel can be armed through a contact connected to a zone programmed
by the installer as key zone.
Every time the contact is opened, all the programs that contain the key zone are
armed.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer. If the programs selected contain delayed zones, these are only armed on
expiry of the exit time. Once the exit time has expired, the yellow program LED are lit
and remain lit until disarming of these programs. If the programs selected do not
contain delayed zones, the programs in question are armed immediately.
6.1.5 AUTOMATIC ARMING
The control panel can be armed automatically using the 32 timers. Therefore, it is
possible to schedule arming with a determined frequency and at a determined time
acting on determined programs.
WARNING OF AUTOMATIC ARMING
At the time and for the period of time programmed by the installer on the display is
viewed a warning of imminent automatic arming and blink the yellow program LED on
the console.
According to programming, the buzzers of the consoles are activated, too.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer. If the programs selected contain delayed zones, these are only armed on
expiry of the exit time.
Once the exit time has expired, the yellow program LED become lit and remain lit until
disarming of these programs. If the programs selected do not contain delayed zones,
the programs in question are armed immediately on disappearance of warning of
automatic arming.
ABORT OF AUTOMATIC ARMING
Automatic arming can be aborted in the following way:
>
Enter the master code
>
Select the timer menu
>
Select the timer to be blocked
Arming
automatic
WARNING
Arming through key zone is direct, i.e. the exclusion of zones is
not
possible.
It is not permitted in case of trouble/general alarm or fault (low battery, power failure etc.). At the
attempt at doing so, on the display is viewed
! ARM. DENIED !
followed by the kind of alarm.
WARNING
Automatic arming is direct, i.e. the exclusion of zones is
not
possible.
It is always executed even in presence of trouble/general alarm or fault (low battery, power failure
etc.).
WARNING
Quick arming is only permitted through the consoles that have been programmed appropriately by
the installer.
It is not permitted in case of trouble/general alarm or fault (low battery, power failure etc.). At the
attempt at doing so, on the display is viewed
! ARM. DENIED !
followed by the kind of alarm.
Содержание TP16-256
Страница 4: ...IV Installer Manual TP16 256...
Страница 12: ...Index Installer Manual TP16 256 8...
Страница 16: ...General Features Installer Manual TP16 256 1 4...
Страница 18: ...Hardware Installer Manual TP16 256 2 2...
Страница 30: ...Hardware Installer Manual TP16 256 2 14...
Страница 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Страница 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Страница 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Страница 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Страница 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Страница 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Страница 86: ...Set up Installer Manual TP16 256 3 6...
Страница 91: ...TP16 256 Installer Manual Set up 3 11...
Страница 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Страница 196: ...Control by Console Installer Manual TP16 256 6 16...
Страница 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Страница 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Страница 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Страница 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Страница 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Страница 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...