Programming by Console
5-27
-
Dial the number and replace the receiver after the first ring
-
Call again after 6 but no later than 60 seconds from the first call
If the control panel receives the second call within 6 to 60 seconds from the
first one, interrupted after the first ring, it answers immediately.
SELECTION OF THE FUNCTION
+
yw
to select the function
+
#
YES
to confirm the selection
Commands available
+
#
YES
to enable the function
+
*
NO
to disable the function
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
5.15.2
PABX NUMBER
If the control panel is connected to a telephone line after a private automatic branch
exchange (PABX) switchboard, to capture the line it is necessary to dial a PABX
number of 1 to 16 digits.
Commands available
+
yw
to delete an existing number
+
#*
to insert the DTMF symbols #(hash) and *(star)
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
5.15.3
CONFIGURATION OF THE CHANNELS
The incorporated telephone section provides 8 independent channels (A...H) that are
individually programmable for the transmission of the events to private persons as
well as monitoring stations.
Every channel can be programmed with a description, a principal and a reserve
telephone number, a transmission protocol and a proper ID code.
The principal telephone number is always called first and the reserve number is called
if no connection could be established under the principal one. If none of the two calls
is successful (either because there is no answer or because the line is busy), 4 more
attempts are made for each of them alternating the principal with the reserve number.
Every channel can be programmed so as to transmit alarm signaling or other data
using either digital protocols or pre-recorded vocal messages that are composed of
words taken from the onboard vocabulary. For digital data transmission, it is
necessary to define a digital protocol according to the kind of device (Tecnoalarm or
non-Tecnoalarm device) connected to and the ID code. The system is compatible with
the most commonly used digital protocols (see table).
SELECTION OF THE CHANNEL
+
yw
to select the channel
+
#
YES
to confirm the selection
Submenus
z
First number
Principal telephone number (max. 15 digits)
z
Second number
Reserve telephone number (max. 15 digits)
z
ID
Channel identification code needed for digital data
transmission (2 to 6 digits)
z
Format
Transmission protocol (3-digit codes - see table)
5.15.3.1
PROGRAMMING OF THE TELEPHONE NUMBERS
SELECTION OF THE NUMBER
+
yw
to select the number
+
#
YES
to confirm the selection
Commands available
+
yw
to delete an existing number
+
#*
to insert the DTMF symbols #(hash) and *(star)
+
MEM
to insert a pause
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
Telephone
2
PABX
Telephone
3
Channel A
Telephone
4
Channel B
Telephone
5
Channel C
Telephone
6
Channel D
Telephone
7
Channel E
Telephone
8
Channel F
Telephone
9
Channel G
Telephone
10
Channel H
Channel A
1
First number
Channel A
2
Second number
WARNING
The channels have all the same priority. The alarms are served in order of occurrence, exception
made of the hold-up alarm. If a hold-up alarm is released while the system is transmitting another
event, the active call is interrupted and the hold-up alarm is transmitted immediately. Aterwards, the
interrupted phone call restarts.
Содержание TP16-256
Страница 4: ...IV Installer Manual TP16 256...
Страница 12: ...Index Installer Manual TP16 256 8...
Страница 16: ...General Features Installer Manual TP16 256 1 4...
Страница 18: ...Hardware Installer Manual TP16 256 2 2...
Страница 30: ...Hardware Installer Manual TP16 256 2 14...
Страница 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Страница 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Страница 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Страница 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Страница 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Страница 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Страница 86: ...Set up Installer Manual TP16 256 3 6...
Страница 91: ...TP16 256 Installer Manual Set up 3 11...
Страница 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Страница 196: ...Control by Console Installer Manual TP16 256 6 16...
Страница 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Страница 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Страница 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Страница 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Страница 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Страница 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...