Control by Console
Installer Manual -
TP16-256
6-12
Abort telephone?
* NO # YES
6.3.6 DEACTIVATION OF BY-PASS ON EXPIRY OF MAXIMUM
BY-PASS TIME
If a maximum by-pass time has been programmed by the installer, on expiry of this
time the by-pass is automatically deactivated.
WARNING OF ARMING
For a period of time programmed by the installer before expiry of the maximum by-
pass time, on the display is viewed a warning of imminent arming due to expiry of
maximum by-pass time and the yellow program LED on the console become lit.
According to programming, the buzzers of the consoles are activated, too.
6.4
ACTIVATION/DEACTIVATION REMOTE
CONTROLS
The master programming menu permits the manual activation and deactivation of the
remote controls.
Enter the master code (default 12345)
+
12345
master code (default)
+
yw
to select the remote controls menu
+
yw
to select the remote controls to activate/deactivate
Commands available
+
#
to activate the remote control
+
*
to deactivate the remote control
+
EXIT
to confirm and quit
QUICK ACTIVATION/DEACTIVATION (IF ENABLED)
If the quick menu of the consoles is enabled, the manual activation and deactivation of
the remote controls without code is possible.
+
yw
to select the remote controls to activate/deactivate
+
#
to activate the remote control
+
*
to deactivate the remote control
+
EXIT
to confirm and quit
6.5
MANUAL COMMUNICATOR BLOCK
During a telephone call, to stop manually the active alarm call cycle and those waiting
enter a code enabled for the manual block of the telephone calls (master or one of the
first 9 standard user codes) followed by the EXIT key, e.g. master code (default code
12345):
+
12345
EXIT
Commands available
+
#
to block the telephone calls
+
*
to abort the block of the telephone calls and quit
Arming
Deact. by-pass
WARNING
The block of the telephone calls is only permitted with master code or one of the first 9 standard user
codes. The blocking command stops all the active alarm calls cycles as well as those waiting.
The block of the telephone calls is not permitted in case of hold-up alarm. In this case, the cycle
continues uninterrupted.
Menu
1
Remote ctrl
Remote ctrl
1
Remote ctrl 01
Rem. ctrl 01
1
Activation
[ # ]
Содержание TP16-256
Страница 4: ...IV Installer Manual TP16 256...
Страница 12: ...Index Installer Manual TP16 256 8...
Страница 16: ...General Features Installer Manual TP16 256 1 4...
Страница 18: ...Hardware Installer Manual TP16 256 2 2...
Страница 30: ...Hardware Installer Manual TP16 256 2 14...
Страница 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Страница 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Страница 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Страница 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Страница 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Страница 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Страница 86: ...Set up Installer Manual TP16 256 3 6...
Страница 91: ...TP16 256 Installer Manual Set up 3 11...
Страница 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Страница 196: ...Control by Console Installer Manual TP16 256 6 16...
Страница 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Страница 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Страница 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Страница 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Страница 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Страница 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...