Using via Digital Data Communication
------------------------------------------------------------------------------------
77
[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]
:Setes Output Current
Function:Sets the output current
Format:[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf>
Type:SET command, QUERY command
Parameters:Range varies on the model and the number of parallel connected devices
Response:Same as parameters
Output Current(A) Ranges
Model(Type)
No. of
Parallel
Connected Devices
400H/HA
800H/HA
1600H/HA
1(Idependent Operation)
0.000~5.250
0.00~10.50
0.00~21.00
2
0.00~10.50
0.00~21.00
0.00~42.00
3
0.00~15.75
0.00~31.50
0.00~63.00
4
0.00~21.00
0.00~42.00
0.00~84.00
5
0.00~26.25
0.00~52.50
0.0~105.0
6
0.00~31.50
0.00~63.00
0.0~126.0
7
0.00~36.75
0.00~73.50
0.0~147.0
8
0.0~42.00
0.00~84.00
0.0~168.0
9
0.00~47.25
0.00~94.50
0.0~189.0
10
0.00~52.50
0.0~105.0
0.0~210.0
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
ZX-S-400H(Idependent Operation)
CURR 5
CURR?
5.000
Содержание ZX-S-H Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Страница 37: ...Basic Operations 33 This is blank page ...
Страница 59: ...Useful Function 55 This is blank page ...
Страница 115: ...Using via Digital Data Communication 111 This is blank page ...
Страница 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Страница 147: ...Special Loads 143 This is blank page 守 ...
Страница 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Страница 189: ...Appendix 185 ZX S 800H 800HA ...
Страница 190: ...Appendix 186 ZX S 1600H 1600HA ...