OUTPut[:STATe]
:Sets Output ON/OFF
Function:Sets the Output ON/OFF
Format:OUTPut[:STATe] <String>
Type:SET command, QUERY command
Paramters: ON…Output ON
OFF…Output OFF
Response: Same as parameter
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as series operation slave unit
・While operating as parallle operation slave unit
<Ex.>
OUTP ON
OUTP?