Controlling with External Analog & Contact Signals
------------------------------------------------------------------------------------
127
3.Output Voltage Control with External Resistance (C)
This sections describes how to set the output voltage zero
when the external resistance value is 10kΩ.
The output voltage is derived from the following formula.
Output Voltage[V]=Max. Output Voltage[V]- Max. Output Voltage[V]×
The output accuracy for the external resistance,
is the set voltage±(0.1%
of Rated Output Voltage).
Connecting
Connect the resistor to accessory connector terminals No.7 and 19.
IN
OUT
19
7
外部抵抗
0~10k
Ω
Setting Procedures
Set to parameter 4 (External Resistance Type C) according to the procedure on page 125.
MAX
0
外部抵抗
出
力
電
圧
CV_RC
10k
Ω
The External Resistance A, B, and C and the External Voltage cannot
be used together to control the output.
Caution
Output v
olt
age
External Resistance
External
Resistance
External Resistance[k
Ω
]
10
The system is a fail safe method and is such that if the External
Resistance opens, the Output Voltage will become zero.
MEMO
Содержание ZX-S-H Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Страница 37: ...Basic Operations 33 This is blank page ...
Страница 59: ...Useful Function 55 This is blank page ...
Страница 115: ...Using via Digital Data Communication 111 This is blank page ...
Страница 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Страница 147: ...Special Loads 143 This is blank page 守 ...
Страница 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Страница 189: ...Appendix 185 ZX S 800H 800HA ...
Страница 190: ...Appendix 186 ZX S 1600H 1600HA ...