Special Loads
------------------------------------------------------------------------------------
142
Pulse Current Loads
If the load current exceeds the constant current (current limit) value for even a moment, the constant current
circuits will trigger. Further, if the output power exceeds the rating even for a moment the power limit circuit
will trigger. In these cases, the output voltage will become unstable.
Please take caution so that the peak current does not exceed the current limit value when the load current is
in a pulsing state. This cannot be determined by this device’s ammeter alone due that it only displays the
average output current value.
If the constant current circuit (power limit circuit) is triggered intermittently by the peak current, the CC lamp
or LIMIT lamp will appear dimly lit or blinking.
For this type of load, stability can be improved by connecting high-capacity capacitors to the load in parallel.
For Pulse Current Loads
Peak Current
+
-
Pulse
Load
+
Average Value
Current Limit Value
Current Wave form due to
Current Limit
Original Current Wave form
0A
Load Current Wave form
Improved with Parallel Capacitors
-
Содержание ZX-S-H Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Страница 37: ...Basic Operations 33 This is blank page ...
Страница 59: ...Useful Function 55 This is blank page ...
Страница 115: ...Using via Digital Data Communication 111 This is blank page ...
Страница 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Страница 147: ...Special Loads 143 This is blank page 守 ...
Страница 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Страница 189: ...Appendix 185 ZX S 800H 800HA ...
Страница 190: ...Appendix 186 ZX S 1600H 1600HA ...