
Useful Function
------------------------------------------------------------------------------------
46
Linearity Compensation
This function provides a high output setting accuracy by measuring and compensating the nonlinearity of the output
caused by feedback systems or DA converters/Error Amplifiers used as a DC power supply voltage or current
reference value. This is normally used when the compensation function is turned ON (Parameter 1 or 2).
Setting Procedures
Press the Function “FUNC.” key.
FUNC. lamp will light.
Settings Item Number will display on the top “Number
Display” and parameters on the bottom Number Display.
Select Item Number 13 with the VOLTAGE dial.
Set Compensation Mode with CURRENT dial.
0=Compensation Function is turned OFF
1=Once compensation has concluded, the
Output is then turned ON, the set values
are changed, and the compensation value
is maintained until there is a change in the
Output mode (CV/CC).
2=Compensates continually (200ms cycles)
Press the FUNC. key again to finish.
Returns Number Display to measurement display mode.
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
Содержание ZX-S-H Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Страница 37: ...Basic Operations 33 This is blank page ...
Страница 59: ...Useful Function 55 This is blank page ...
Страница 115: ...Using via Digital Data Communication 111 This is blank page ...
Страница 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Страница 147: ...Special Loads 143 This is blank page 守 ...
Страница 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Страница 189: ...Appendix 185 ZX S 800H 800HA ...
Страница 190: ...Appendix 186 ZX S 1600H 1600HA ...