ALM Level
ALM level command corresponds to external output settings for alarm reset and status information.
Command Name
Summary
Command Type
ALM
-
-
:CLEar
Executes alarm reset
SET only
:CONTAin
-
-
:CC
Sets whether to include CC_STS in LEVEL1_ALM or not
Both
:CV
Sets whether to include CV_STS in LEVEL1_ALM or not
Both
:PL
Sets whether to include PL_STS in LEVEL1_ALM or not
Both
:PONB
Sets whether to include P_ON_B in LEVEL1_ALM or not
Both
ALM:CLEar
: Executes Alarm Reset
Function:Executes alarm reset (Cancels generated Over Voltage/Over Current alarm)
Format:ALM:CLEar
Type:SET command only
No parameters
<Ex.>
ALM:CLE
ALM:CONTain:CC
:Sets whether to contain CC_STS in LEVEL1_ALM
Function: Sets whether to contain CC_STS status in LEVEL1_ALM output condition.
Same settings as FUNCTION Settings Item 75
Format:ALM:CONTain:CC <NRf>
Type:SET command, QUERY command
Parameters: 0 ・・・Does not include in LEVEL1_ALM
1 ・・・Includes in LEVEL1_ALM
Response: 0, 1
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・If analog option is not attached
・While operating as a parallel operation slave unit
・Sequence operation in progress
<Ex.>
ALM:CONT:CC 1
ALM:CONT:CC?
1
Note: Execute alarm reset only once cause has been resolved.
Caution
Содержание ZX-S-H Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Страница 37: ...Basic Operations 33 This is blank page ...
Страница 59: ...Useful Function 55 This is blank page ...
Страница 115: ...Using via Digital Data Communication 111 This is blank page ...
Страница 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Страница 147: ...Special Loads 143 This is blank page 守 ...
Страница 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Страница 189: ...Appendix 185 ZX S 800H 800HA ...
Страница 190: ...Appendix 186 ZX S 1600H 1600HA ...