Using via Digital Data Communication
------------------------------------------------------------------------------------
108
TK3
:Read-Back Status Information
Function:Retrives the status information from the ZX power supply with the specified device address
Format:TK3
Read-Back Format:A*1,STAT*2
*1、*2:Read-Back Value
Read-Back Value:
*1:Device address of the responed ZX power supply
*2:Status is represents as 0 or 1
STAT*******
6 0
Retrived Status Information List
Bit
Status Name
Summary
1
0
0
P-ON(M)_STS
P-ON (Master) Status
Main Power Supply
ON
Main Power Supply
OFF
1
OHP_ALM
OHP(Over Heating Protection)
Error
Error
Normal
2
PL_STS
Power Delimiter Operation
Status
Power Delimiter
running
Normal
3
OCP_ALM
OCP (Over Current
Protection ) Error
Error
Normal
4
OVP_ALM
OVP (Over Voltage
Protection) Error
Error
Normal
5
CC_STS
CC Operation Status
CC operating
Not CC
6
CV_STS
CV Operation Status
CV operating
Not CV
<Ex.>A1,TK3
A1,STAT1000010