Using via Digital Data Communication
------------------------------------------------------------------------------------
68
ALM:CONTain:PONB
:Sets whether to include P_ON_B in LEVEL1_ALM
Function: Sets whether to include P_ON_B status in LEVEL1_ALM output condition
Same settings as FUNCTION Settings Item 76
Format:ALM:CONTain:PONB <NRf>
Type:SET command, QUERY command
Parameters: 0 ・・・Does not include in LEVEL1_ALM
1 ・・・Includes in LEVEL1_ALM
Response: Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・If analog option is not attached(Type which A is not attached to end of name, like ZX-S-400H)
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
ALM:CONT:PONB 0
ALM:CONT:PONB?
0