Using via Digital Data Communication
------------------------------------------------------------------------------------
105
MC
:Sets Output Current
Function:Sets the output current
Format:MC* *:Set value within range
Range:Values other than ranges result in parameter errors.
Range varies on the model and number of parallel connected devices.
Output Current Range
Model(Type)
No. of
Parallel
Connected Devices
400H/HA
800H/HA
1600H/HA
1(Idependent Operation)
0.00~5.250
0.00~10.50
0.00~21.00
2
0.00~10.50
0.00~21.00
0.00~42.00
3
0.00~15.75
0.00~31.50
0.00~63.00
4
0.00~21.00
0.00~42.00
0.00~84.00
5
0.00~26.25
0.00~52.50
0.0~105.0
6
0.00~31.50
0.00~63.00
0.0~126.0
7
0.00~36.75
0.00~73.50
0.0~147.0
8
0.00~42.00
0.00~84.00
0.0~168.0
9
0.00~47.25
0.00~94.50
0.0~189.0
10
0.00~52.50
0.0~105.0
0.0~210.0
<Ex.>A1,MC42.0
MV
:Sets Output Voltage
Function:Sets the output voltage
Format:MV* *:Set value within range
Range:0.0~672.0
<Ex.>A1,OV10.5