Chapter 5
Servicing Infrastructure Boards and Components
5-5
5.2.1
Removing a Fan Power Board
1. Prepare the server for service.
a. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.5, “Extending the Server to the Maintenance Position” on
page 2-5
.
Note –
If you are removing the fan power boards to access the paddle card or drive
cage, you must remove the server from the rack. See
Section 2.6, “Removing a Server
From the Rack” on page 2-7
.
d. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
e. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
2. Remove the fan modules.
Note –
If you are replacing a defective fan power board, remove only the fan
modules that are necessary to remove the defective fan power board.
See
Section 3.3.4, “Removing a Fan Module” on page 3-11
.
3. Remove the Phillips screw that secures the fan power board to the chassis
(
FIGURE 5-3
).
4. Slide the fan power board to the left to disengage it from the paddle card.
5. Remove the fan power board from the system and place it on an antistatic mat.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...