4-38
Sun Fire X4140 Server Service Manual • September 2010
Note –
Use the command
socflash -h
to get a complete option listing.
4. After a successful flash, perform an AC power cycle or reset the SP using the
following command:
socflash -r
Note –
Using
-r
(resetting the SP hardware) can cause the VGA display to become
disrupted.
Note –
The BIOS is not upgraded by this emergency recovery procedure. Perform a
2nd ILOM-based flash upgrade, to update the BIOS version.
Note –
This emergency flash recovery procedure returns the SP to default
configuration.
5. Press F2 to enter system BIOS and verify that the flash device is in the boot
order.
6. After a successful flash, remove the flash drive from the USB port.
7. AC power cycle the server.
Wait at least 2 minutes to let SP come up first.
8. Power on the server and enter BIOS.
9. Confirm following items are correct in BIOS:
a. BMC Firmware Revision is correct on the Main page.
b. Status of BMC is working in Advanced -> IPMI 2.0 Configuration page.
10. Exit BIOS and start the operating system.
4.11
Using the Reset and NMI Switches
Caution –
Do not use the Reset and NMI Dump switches unless you are instructed
to do so by a Field Service engineer.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...