Chapter 4
Servicing Motherboard Components
4-31
d. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
e. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
2. Identify which processor to remove.
Processor 0 is closest to the PSU bay.
3. Unscrew the two heatsink screws.
4. Twist the heatsink slightly to break the seal with grease, and then lift off the
heatsink.
5. Disengage the lever by pushing down and moving to the side, and then rotating
upward.
6. Open the pressure frame.
7. Remove the processor.
8. Place the removed processor in an anti-static package.
Caution –
Avoid damaging the pins on the processor when placing an old processor
in the return package. Use the correct processor package.
4.8.3
Installing a Processor FRU
To install a processor FRU.
1. Prepare the server for service.
a. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.5, “Extending the Server to the Maintenance Position” on
page 2-5
.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...