Chapter 4
Servicing Motherboard Components
4-19
FIGURE 4-10
Installing a PCIe Card
4.5
Servicing the Battery
The following topics are covered:
■
Section 4.5.1, “Removing the Battery” on page 4-20
■
Section 4.5.2, “Installing the Battery” on page 4-20
The battery maintains system time when the server is powered off and a time server
is unavailable. If the server fails to maintain the proper time when powered off and
not connected to a network, replace the battery.
You need a small (No. 1 flat-blade) screwdriver.
Note –
CRU
: This customer-replaceable unit can be replaced by anyone.
Caution –
Ensure that all power is removed from the server before removing or
installing the battery. You must disconnect the power cables from the system before
performing this procedure.