Chapter 4
Servicing Motherboard Components
4-11
4.2.1
Removing the Air Baffle
1. Prepare the server for service.
a. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.5, “Extending the Server to the Maintenance Position” on
page 2-5
.
d. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
e. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
2. Open the air baffle.
Slide the duct off of the screws and remove the air baffle as shown in
FIGURE 4-5
.
3. Set the air baffle aside.
FIGURE 4-5
Removing the Air Baffle