5-8
Sun Fire X4140 Server Service Manual • September 2010
c. Slide the server out of the rack.
See
Section 2.5, “Extending the Server to the Maintenance Position” on
page 2-5
.
d. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
e. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
2. If you are servicing the drives backplane, remove all drives.
See
Section 3.2.4, “Removing a Hard Drive or SSD” on page 3-5
.
Note –
Make a note of the drive locations before removing them from the system.
You will need to install the drives in the correct locations when reassembling the
system.
3. If you are servicing the drive backplane, remove the DVD/USB module.
See
Section 5.1.1, “Removing the DVD/USB Module” on page 5-2
.
4. Remove the fan modules.
See
Section 3.3.4, “Removing a Fan Module” on page 3-11
.
5. Remove the No. 2 Phillips screws securing the drives cage to the chassis
(
FIGURE 5-5
[1] and [2]).
Two screws secure the disk cage to each side of the chassis.
6. Slide the drives cage forward to disengage the backplane from the paddle cards
(
FIGURE 5-5
[3]).
7. Lift the drives cage up and disconnect the drives data cables (
FIGURE 5-5
[4]).
Press the connector release button to release the cable.
8. Set the drives cage on an antistatic mat.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...