4-22
Sun Fire X4140 Server Service Manual • September 2010
4.6.1
Removing the Motherboard Assembly
1. Prepare the server for service.
a. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
c. Remove the server from the rack.
See
Section 2.6, “Removing a Server From the Rack” on page 2-7
.
d. Extend the server into the maintenance position.
See
Section 2.5, “Extending the Server to the Maintenance Position” on
page 2-5
.
e. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
f. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
2. Remove the air baffle.
See
Section 4.2.1, “Removing the Air Baffle” on page 4-11
.
3. Remove the PCIe cards and risers.
See
Section 4.3.1, “Removing a PCIe Riser” on page 4-13
. Make note of the location
of expansion cards in the PCIe risers.
4. Disconnect the power distribution board ribbon cable.
5. If you are replacing the motherboard, remove the DDR2 DIMMs.
Make note of the memory configuration so that you can install the DDR2 DIMMs
in the replacement motherboard.
6. Disconnect the drive data cables.
Caution –
The drive data cables are delicate. Ensure they are safely out of the way
when servicing the motherboard.
7. Remove the processor heat sinks from the motherboard assembly.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...