5-2
Sun Fire X4140 Server Service Manual • September 2010
5.1
Servicing the DVD/USB Module
The DVD-ROM drive and front USB board are mounted in a removable module that
is accessible from the front panel of the system. The DVD/USB module must be
removed from the drive cage to service the drives backplane.
Note –
CRU
: This customer-replaceable unit can be replaced by anyone.
5.1.1
Removing the DVD/USB Module
1. Remove media from the drive.
2. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
3. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
4. Remove the Sun Fire X4140 Server HDD7 hard drive.
See
“Server Front Panel” on page 3-3
for drives locations.
5. Release the DVD/USB module from the drives backplane (
FIGURE 5-1
).
Use the finger indent in the drive bay below the DVD/USB module to detach the
module from the backplane.
6. Slide the DVD/USB module out of the drive cage.
7. Place the module on an antistatic mat.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...