Chapter 2
Preparing to Service the System
2-5
2.5
Extending the Server to the Maintenance
Position
The following components can be serviced with the server in the maintenance
position:
■
Hard drives
■
SSDs
■
Fan modules
■
Power supplies
■
DVD/USB module
■
Fan power boards
■
DDR2 DIMMs
■
PCIe cards
■
Motherboard battery
If the server is installed in a rack with extendable slide rails, use this procedure to
extend the server to the maintenance position.
1. (Optional) Issue the following command from the
->
prompt to locate the
system that requires maintenance.
After you have located the server, press the Locator LED/Locator button to turn it
off.
2. Verify that no cables will be damaged or will interfere when the server is
extended.
Although the cable management arm (CMA) that is supplied with the server is
hinged to accommodate extending the server, you should ensure that all cables
and cords are capable of extending.
3. Extend the lower floor arm on the cabinet for safety, if present.
4. From the front of the server, release the two slide release latches (
FIGURE 2-3
).
Squeeze the green slide release latches to release the slide rails.
->
set /SYS/LOCATE value=fast_blink
Locator indicator is on.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...