3-16
Sun Fire X4140 Server Service Manual • September 2010
3. Release the cable management arm (CMA) (
FIGURE 3-10
).
The CMA is located at the rear of the server rack.
FIGURE 3-10
Releasing the Cable Management Arm
a. Press and hold the tab.
b. Rotate the cable management arm out of the way so that you can access the
power supply.
4. Disconnect the power cord from the faulty power supply.
5. Grasp the power supply handle and press the release latch (
FIGURE 3-11
).
6. Pull the power supply out of the chassis.