5-26
Sun Fire X4140 Server Service Manual • September 2010
3. Open the latches on the PDB connector.
Ensure that the key of the cable lines up with the slot on the connector.
4. Push the cable connector into the PDB connection until seated.
The latches should be above the connector housing.
5. Carefully align the motherboard connector to the motherboard pin field.
Gently press the connector down until seated. If you feel significant resistance,
stop and check the pin alignment.
6. Return the server to operation.
a. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
b. Install the server into the rack.
See
Section 6.2, “Reinstalling the Server in the Rack” on page 6-3
.
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.