Chapter 4
Servicing Motherboard Components
4-35
3. At the BIOS screen, move to the Security Screen tab.
4. Change the password.
5. Save and Exit the BIOS.
The system restarts.
4.9.3
Resetting CMOS NVRAM Using a Jumper
To clear the CMOS NVRAM using a jumper:
1. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
2. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
3. Extend the server into the maintenance position.
See
Section 2.5, “Extending the Server to the Maintenance Position” on page 2-5
.
4. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
5. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
6. Locate the jumper J1802
The jumper is on the rear of the motherboard, opposite side of the power supply.
7. Place the jumper on position 1-3.
8. Power on the server and boot until message about NVRAM has been cleared.
9. Power off the server, and remove AC power.
10. Remove jumper from position 1-3, and replace it back in its original location.
11. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
12. Slide the server into the rack.
See
Section 6.3, “Returning the Server to the Normal Rack Position” on page 6-4
.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...