Chapter 5
Servicing Infrastructure Boards and Components
5-7
a. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
b. Slide the server into the rack.
See
Section 6.3, “Returning the Server to the Normal Rack Position” on
page 6-4
.
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.
5.3
Servicing the Drives Cage
You must remove the drive cage to access the following components:
■
Drives backplane
■
Front control panel light pipe assemblies
Note –
FRU
: This field-replaceable unit should be replaced only by qualified service
technicians. Contact your Sun Service representative for assistance.
Caution –
Ensure that all power is removed from the server before removing or
installing the drives cage. You must disconnect the power cables before performing
this procedure.
5.3.1
Removing the Drives Cage
1. Prepare the server for service.
a. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...